Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.950
Filtrar
1.
Mikrochim Acta ; 191(5): 268, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38627271

RESUMO

Hybrid nanozyme graphene quantum dots (GQDs) deposited TiO2 nanotubes (NTs) on titanium foil (Ti/TiO2 NTs-GQDs) were manufactured by bestowing the hybrid with the advantageous porous morphology, surface valence states, high surface area, and copious active sites. The peroxidase-like activity was investigated through the catalytic oxidation of chromogenic substrate 3,3',5,5'-tetramethylbenzidine (TMB) in the presence of H2O2, which can be visualized by the eyes. TiO2 NTs and GQDs comprising oxygen-containing functional groups can oxidize TMB in the presence of H2O2 by mimicking peroxidase enzymes. The peroxidase-mimicking activity of hybrid nanozyme was significantly escalated by introducing light illumination due to the photosensitive features of the hybrid material. The peroxidase-like activity of Ti/TiO2 NTs-GQDs enabled H2O2 determination over the linear range of 7 to 250 µM, with a LOD of 2.1 µM. The satisfying peroxidase activity is possibly due to the unimpeded access of H2O2 to the catalyst's active sites. The porous morphology provides the easy channeling of reactants and products. The periodic structure of the material also gave rise to acceptable reproducibility. Without material functionalization, the Ti/TiO2 NTs-GQDs can be a promising substitute for peroxidases for H2O2 detection.


Assuntos
Benzidinas , Grafite , Nanotubos , Pontos Quânticos , Grafite/química , Peroxidase/química , Pontos Quânticos/química , Peróxido de Hidrogênio/química , Reprodutibilidade dos Testes , Nanotubos/química
2.
ACS Appl Mater Interfaces ; 16(15): 18564-18573, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38567738

RESUMO

Replicating the sense of smell presents an ongoing challenge in the development of biomimetic devices. Olfactory receptors exhibit remarkable discriminatory abilities, including the enantioselective detection of individual odorant molecules. Graphene has emerged as a promising material for biomimetic electronic devices due to its unique electrical properties and exceptional sensitivity. However, the efficient detection of nonpolar odor molecules using transistor-based graphene sensors in a gas phase in environmental conditions remains challenging due to high sensitivity to water vapor. This limitation has impeded the practical development of gas-phase graphene odor sensors capable of selective detection, particularly in humid environments. In this study, we address this challenge by introducing peptide-functionalized graphene sensors that effectively mitigate undesired responses to changes in humidity. Additionally, we demonstrate the significant role of humidity in facilitating the selective detection of odorant molecules by the peptides. These peptides, designed to mimic a fruit fly olfactory receptor, spontaneously assemble into a monomolecular layer on graphene, enabling precise and specific odorant detection. The developed sensors exhibit notable enantioselectivity, achieving a remarkable 35-fold signal contrast between d- and l-limonene. Furthermore, these sensors display distinct responses to various other biogenic volatile organic compounds, demonstrating their versatility as robust tools for odor detection. By acting as both a bioprobe and an electrical signal amplifier, the peptide layer represents a novel and effective strategy to achieve selective odorant detection under normal atmospheric conditions using graphene sensors. This study offers valuable insights into the development of practical odor-sensing technologies with potential applications in diverse fields.


Assuntos
Técnicas Biossensoriais , Grafite , Receptores Odorantes , Odorantes , Grafite/química , Gases , Estereoisomerismo , Receptores Odorantes/química , Peptídeos
3.
Chemosphere ; 355: 141728, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38499073

RESUMO

Considering the plethora of work on the exceptional environmental performance of 2D nanomaterials, there is still a missing link in addressing their practical application in point-of-use (POU) water treatment. By reviewing the exceptional environmental performance of 2D nanomaterials with specific emphasis on graphene and its derivatives, this review aims at inspiring further discussions and research in graphene-based POU water treatment with particular focus on the removal of emerging contaminants of concern (ECCs), which is largely missing in the literature. We outlined the prevalence of ECCs in the environment, their health effects both on humans and marine life, and the potential of efficiently removing them from water using three-dimensional graphene-based macrostructures to ensure ease of adsorbent recovery and reuse compared to nanostructures. Given various successful studies showing superior adsorption capacity of graphene nanosheets, we give an account of the recent developments in graphene-based adsorbents. Moreover, several cost-effective materials which can be easily self-assembled with nanosheets to improve their environmental performance and safety for POU water treatment purposes were highlighted. We highlighted the strategy to overcome challenges of adsorbent regeneration and contaminant degradation; and concluded by noting the need for policy makers to act decisively considering the conservative nature of the water treatment industry, and the potential health risks from ingesting ECCs through drinking water. We further justified the need for the development of advanced POU water treatment devices in the face of the growing challenges regarding ECCs in surface water, and the rising cases of drinking water advisories across the world.


Assuntos
Água Potável , Grafite , Nanoestruturas , Poluentes Químicos da Água , Purificação da Água , Humanos , Grafite/química , Nanoestruturas/química , Purificação da Água/métodos , Adsorção , Poluentes Químicos da Água/química
4.
ACS Appl Bio Mater ; 7(4): 2511-2518, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38512069

RESUMO

High-fidelity patterning of DNA origami nanostructures on various interfaces holds great potential for nanoelectronics and nanophotonics. However, distortion of a DNA origami often occurs due to the strong interface interactions, e.g., on two-dimensional (2D) materials. In this study, we discovered that the adsorption of silica precursors in rapid silicification can prevent the distortion caused by graphene and generates a high shape-fidelity DNA origami-silica composite on a graphene interface. We found that an incubation time of 1 min and silicification time of 16 h resulted in the formation of DNA origami-silica composites with the highest shape fidelity of 99%. By comparing the distortion of the DNA origami on the graphene interface with and without silicification, we observed that rapid silicification effectively preserved the integrity of the DNA origami. Statistical analysis of scanning electron microscopy data indicates that compared to bare DNA origami, the DNA origami-silica composite has an increased shape fidelity by more than two folds. Furthermore, molecular dynamics simulations revealed that rapid silicification effectively suppresses the distortion of the DNA origami through the interhelical insertion of silica precursors. Our strategy provides a simple yet effective solution to maintain the shape-fidelity DNA origami on interfaces that have strong interaction with DNA molecules, expanding the applicable interfaces for patterning 2D DNA origamis.


Assuntos
Grafite , Nanoestruturas , Microscopia de Força Atômica , Grafite/química , Nanoestruturas/química , DNA/química , Dióxido de Silício/química
5.
Environ Sci Technol ; 58(13): 5963-5973, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38512311

RESUMO

In this study, characteristics of oxidation debris (OD) and its stripping mechanism from graphene oxide (GO) were explored. The results demonstrated that OD contains three components, namely, protein-, fulvic acid-, and humic acid-like substances; among these, protein-like substances with lower molecular weight and higher hydrophilicity were most liable to be stripped from GO and were the primary components stripped from GO at pH < 10, whereas humic acid- and fulvic acid-like substances were stripped from GO at pH > 10. During the stripping of OD, hydrogen bonds from carboxyl and carbonyl were the first to break, followed by hydrogen bonds from epoxy. Subsequently, π-π interactions were broken, and hydrogen bond interactions induced by hydroxyl groups were the hardest to break. After the stripping of OD, the recombination of OD on GO was observed, and regions containing relatively fewer oxygen-containing functional groups were favorable binding sites for the readsorbed OD. The stripping and recombination of OD on GO resulted in an uneven GO surface, which should be considered during the development of GO-based environmental materials and the evaluation of their environmental behavior.


Assuntos
Grafite , Nanoestruturas , Óxidos/química , Substâncias Húmicas/análise , Grafite/química
6.
Biomolecules ; 14(3)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38540784

RESUMO

A hybrid material, consisting of commercially available nitrocellulose (NC) membrane non-covalently modified with amino-polyethylene glycol functionalized reduced graphene oxide (NH2-PEG-rGO) nanoparticles, was successfully synthesized for oligonucleotide extraction. Fourier Transform Infrared Spectroscopy (FTIR) confirmed the modification of the NC membrane, revealing characteristic peaks of both compounds, i.e., NC and NH2-PEG-rGO. Scanning Electron Microscopy (SEM) exhibited morphological changes in the NC/NH2-PEG-rGO hybrid membrane, marked by the introduction of NH2-PEG-rGO particles, resulting in a distinctly smothered surface compared to the porous surface of the NC control membrane. Wettability assays revealed hydrophobic behavior for the NC/NH2-PEG-rGO hybrid membrane, with a water contact angle exceeding 90°, contrasting with the hydrophilic behavior characterized by a 16.7° contact angle in the NC membrane. The performance of the NC/NH2-PEG-rGO hybrid membrane was evaluated for the extraction of ssDNA with fewer than 50 nucleotides from solutions containing various ionic species (MnCl2, MgCl2, and MnCl2/MgCl2). The NC/NH2-PEG-rGO hybrid membrane exhibited optimal performance when incubated in MgCl2, presenting the highest fluorescence emission at 525 relative fluorescence units (r.f.u.). This corresponds to the extraction of approximately 610 pg (≈13%) of the total oligo-DNA, underscoring the efficacy of the pristine material, which extracts 286 pg (≈6%) of oligo-DNA in complex solutions.


Assuntos
Grafite , Óxidos , Óxidos/química , Colódio , Grafite/química , Água , DNA de Cadeia Simples , Extração em Fase Sólida
7.
Biosens Bioelectron ; 254: 116228, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38522233

RESUMO

Detection of superoxide anion (O2·-) levels holds significant importance for the diagnosis and even clinical treatments of oxidative stress-related diseases. Herein, we prepared a composite electrode material to encapsulate copper-zinc superoxide dismutase (SOD1) for biosensing of O2·-. The sensing material consists of gold nanowires (AuNWs), reduced graphene oxide (rGO), carboxymethyl cellulose (CMC) and PEDOT:PSS. CMC provides abundant -COOH to bind SOD1, with a high adsorption coverage of 1.499 × 10-9 mol cm-2 on the sensor surface. rGO and PEDOT endow the composite with significant conductivity, whereas PSS has antifouling capability. Moreover, AuNWs exhibit excellent electrical conductivity and a high aspect ratio, which promotes electron transfer, and ultimately enhances the catalytic performance of the enzyme. Meanwhile, SOD1(Cu2+) catalyzes the dismutation of O2·- to O2 and H2O2, and H2O2 is then electrochemically oxidized to generate amperometric signals for determination of O2·-. The sensor demonstrates outstanding detection performance for O2·- with a low detection limit of 2.52 nM, and two dynamic ranges (14.30 nM-1.34 µM and 1.34 µM-42.97 µM) with corresponding sensitivity of 0.479 and 0.052 µA µM-1cm-2, respectively. Additionally, the calculated apparent Michaelis constant (Kmapp) of 1.804 µM for SOD1 demonstrates the outstanding catalytic activity and the surface-immobilized enzyme's substrate affinity. Furthermore, the sensor shows the capability to dynamically detect the level of O2·- released from living HepG2 cells. This study provides an inovative design to obtain a biocompatible electrochemical sensing platform with plenty of immobilization sites for biomolecules, large surface area, high conductivity and flexibility.


Assuntos
Técnicas Biossensoriais , Grafite , Superóxidos/química , Carboximetilcelulose Sódica , Peróxido de Hidrogênio , Superóxido Dismutase-1 , Técnicas Biossensoriais/métodos , Grafite/química , Superóxido Dismutase/química , Técnicas Eletroquímicas
8.
Biosens Bioelectron ; 255: 116246, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38537430

RESUMO

3-nitrotyrosine (3-NT) is a biomarker closely associated with the early diagnosis of oxidative stress-related disorders. The development of an accurate, cost-effective, point-of-care 3-NT sensor holds significant importance for self-monitoring and clinical treatment. In this study, a selective, sensitive, and portable molecularly imprinted electrochemical sensor was developed. ZIF-67 with strong adsorption capacity was facilely modified on an electrochemically active laser-induced graphene (LIG) substrate (formed ZIF-67/LIG). Subsequently, biocompatible dopamine was chosen as the functional monomer, and interference-free ʟ-tyrosine was used as the dummy template to create molecularly imprinted polydopamine (MIPDA) on the ZIF-67/LIG, endowing the sensor with selectivity. The morphologies, electrochemical properties, and detection performance of the sensor were comprehensively investigated using scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy, and differential pulse voltammetry. To achieve the best performance, several parameters were optimized, including the number of polymerization cycles (15), elution time (60 min), incubation time (7 min), and pH of the buffer solution (6). The turnaround time for this sensor is 10 min. Benefiting from the alliance of MIPDA, ZIF-67, and LIG, the sensor exhibited excellent sensitivity with a detection limit of 6.71 nM, and distinguished selectivity against 11 interfering substances. To enable convenient clinical diagnosis, a customized electrochemical microsensor with MIPDA/ZIF-67/LIG was designed, showcasing excellent reliability and convenience in detecting biological samples without pretreatment. The proposed microsensor will not only facilitate clinical diagnosis and improve patient care, but also provide inspiration for the development of other portable and accurate electrochemical biosensors.


Assuntos
Técnicas Biossensoriais , Grafite , Indóis , Impressão Molecular , Polímeros , Tirosina/análogos & derivados , Humanos , Grafite/química , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes , Limite de Detecção , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Impressão Molecular/métodos , Eletrodos
9.
Biotechnol Bioeng ; 121(5): 1469-1485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38548663

RESUMO

The carbon-based nanostructures have led to the development of theranostic nanoplatforms for simultaneous diagnosis and therapy due to their effective cell membrane-penetration ability, low degree of cytotoxicity, excellent pore volume, substantial chemical stability, and reactive surface. In the last few years, extensive efforts were made to design multifunctional nanoplatform strategies based on carbon nanostructures, involving multimodal imaging, controlled drug release capabilities, sensing in vitro, efficient drug loading capacity, and therapy. Carbon and graphene quantum dots (CQDs and GQDs) were the recent entrants, contingently being assessed for drug delivery and bioimaging. With the advancements, these quantum dots have ignited remarkable research interest and are now widely evaluated for diagnosis, bioimaging, sensing, and drug delivery applications. The last decade has witnessed their remarkable electrical, optical, and biocompatible properties since their inception. It is presumed that both of them have high potential as drug carriers and would serve as the next generation of approaches to address numerous unresolved therapeutic challenges. This review examined the recent advances of CQD and GQD based drug delivery applications, challenges, and future perspectives to pave the way for further studies in the future.


Assuntos
Grafite , Pontos Quânticos , Pontos Quânticos/química , Grafite/química , Carbono , Sistemas de Liberação de Medicamentos , Portadores de Fármacos/química
10.
Biosens Bioelectron ; 253: 116161, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38457864

RESUMO

We herein describe a novel electrochemical strategy to detect hydrogen peroxide (H2O2) by utilizing the peroxidase-mimicking activity of cerium oxide nanoparticles (CeO2 NP) and reduced graphene oxide (rGO). Particularly, CeO2 NP/rGO nanocomposites were deposited on the commercial electrode by a very convenient and direct electrochemical reduction of graphene oxide. Due to the peroxidase-mimicking activity of CeO2 NP and the outstanding electrochemical properties of reduced graphene oxide, the reduction current of H2O2 was greatly enhanced. Based on this strategy, we reliably determined H2O2 down to 1.67 µM with excellent specificity and further validated its practical capabilities by robustly detecting H2O2 present in heterogeneous human serum samples. We believe that this work could serve as a new facile platform for H2O2 detection.


Assuntos
Técnicas Biossensoriais , Cério , Grafite , Nanocompostos , Humanos , Peróxido de Hidrogênio , Grafite/química , Cério/química , Nanocompostos/química , Peroxidases , Técnicas Eletroquímicas
11.
Int J Nanomedicine ; 19: 2691-2708, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38510793

RESUMO

Purpose: Patients afflicted with dry eye disease (DED) experience significant discomfort. The underlying cause of DED is the excessive accumulation of ROS on the ocular surface. Here, we investigated the nitrogen doped-graphene quantum dots (NGQDs), known for their ROS-scavenging capabilities, as a treatment for DED. Methods: NGQDs were prepared by using citric acid and urea as precursors through hydrothermal method. The antioxidant abilities of NGQDs were evaluated through: scavenging the ROS both extracellular and intracellular, regulating the nuclear factor-erythroid 2-related factor (Nrf2) antioxidant pathway of human corneal epithelial cells (HCECs) and their transcription of inflammation related genes. Furthermore, NGQDs were modified by Arg-Gly-Asp-Ser (RGDS) peptides to obtain RGDS@NGQDs. In vivo, both the NGQDs and RGDS@NGQDs were suspended in 0.1% Pluronic F127 (w/v) and delivered as eye drops in the scopolamine hydrobromide-induced DED mouse model. Preclinical efficacy was compared to the healthy and DPBS treated DED mice. Results: These NGQDs demonstrated pronounced antioxidant properties, efficiently neutralizing free radicals and activating the intracellular Nrf2 pathway. In vitro studies revealed that treatment of H2O2-exposed HCECs with NGQDs induced a preservation in cell viability. Additionally, there was a reduction in the transcription of inflammation-associated genes. To prolong the corneal residence time of NGQDs, they were further modified with RGDS peptides and suspended in 0.1% Pluronic F127 (w/v) to create RGDS@NGQDs F127 eye drops. RGDS@NGQDs exhibited superior intracellular antioxidant activity even at low concentrations (10 µg/mL). Subsequent in vivo studies revealed that RGDS@NGQDs F127 eye drops notably mitigated the symptoms of DED mouse model, primarily by reducing ocular ROS levels. Conclusion: Our findings underscore the enhanced antioxidant benefits achieved by modifying GQDs through nitrogen doping and RGDS peptide tethering. Importantly, in a mouse model, our novel eye drops formulation effectively ameliorated DED symptoms, thereby representing a novel therapeutic pathway for DED management.


Assuntos
Síndromes do Olho Seco , Grafite , Polietilenos , Polipropilenos , Pontos Quânticos , Camundongos , Humanos , Animais , Antioxidantes/farmacologia , Espécies Reativas de Oxigênio , Grafite/química , Pontos Quânticos/química , Nitrogênio/química , Peróxido de Hidrogênio , Fator 2 Relacionado a NF-E2 , Poloxâmero , Síndromes do Olho Seco/tratamento farmacológico , Inflamação , Soluções Oftálmicas , Peptídeos
12.
Sci Rep ; 14(1): 6350, 2024 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-38491108

RESUMO

Lung cancer remains the leading cause of cancer mortality worldwide. Small cell lung cancer (SCLC) accounts for 10-15% of cases and has an overall 5-years survival rate of only 15%. Neuron-specific enolase (NSE) has been identified as a useful biomarker for early SCLC diagnosis and therapeutic monitoring. This work reports an electrochemical immunosensing platform based on a graphene-graphitic carbon nitride (g-C3N4) nanocomposite for ultrasensitive NSE detection. The g-C3N4 nanosheets and graphene nanosheets were synthesized via liquid exfoliation and integrated through self-assembly to form the nanocomposite. This nanocomposite was used to modify screen-printed carbon electrodes followed by covalent immobilization of anti-NSE antibodies. The unique properties of the graphene-g-C3N4 composite facilitated efficient antibody loading while also enhancing electron transfer efficiency and electrochemical response. Systematic optimization of experimental parameters was performed. The immunosensor exhibited a wide linear detection range of 10 pg/mL to 100 ng/mL and low limit of detection of 3 pg/mL for NSE along with excellent selectivity against interferences. Real serum matrix analysis validated the applicability of the developed platform for sensitive and accurate NSE quantifica-tion at clinically relevant levels. This novel graphene-g-C3N4 nanocomposite based electro-chemical immunoassay demonstrates great promise for early diagnosis of SCLC.


Assuntos
Biomarcadores , Técnicas Biossensoriais , Neoplasias Pulmonares , Fosfopiruvato Hidratase , Carcinoma de Pequenas Células do Pulmão , Humanos , Biomarcadores/análise , Técnicas Eletroquímicas , Grafite/química , Imunoensaio , Limite de Detecção , Neoplasias Pulmonares/diagnóstico , Fosfopiruvato Hidratase/análise , Carcinoma de Pequenas Células do Pulmão/diagnóstico
13.
Bioelectrochemistry ; 157: 108674, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38460467

RESUMO

Early monitoring of MRSA can effectively mitigate the disease risk by using Penicillin-binding protein 2a (PbP2a) biomarker. Diamino naphthalene-AuNPs decorated graphene (AuNPsGO-DN) nanocomposite was synthesized for a rapid and sensitive immunosensor detecting PbP2a. The synthesized AuNPsGO-DN nanocomposites were characterized by field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (SEM-EDX), Fourier transform infrared spectroscopy (FT-IR), Raman spectroscopy, and X-ray diffraction spectroscopy (XRD). Electrochemical characterization done with cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrical impedance spectroscopy (EIS) techniques. Anti-PbP2a monoclonal antibodies immobilized at AuNPsGO-DN/GCE via covalent bonding. AuNPs enhanced the electrode surface area and the antibodies' loading. Mercaptopropionic acid (MPA) was a linker between the AuNPs and antibodies, orientated the antibodies as opposite to the PbP2a antigen, and improved the sensitivity and specificity. The antiPbP2a/MPA/AuNPsGO-DN/GCE electrode displayed sensitive and selective detection towards the PbP2a antigen in phosphate buffer saline (PBS pH 7.4). The broad linear range from 0.01 to 8000 pg/mL was obtained with LOD of 0.154 pg/mL and 0.0239 pg/mL, respectively. A label-free, simple, and sensitive immunosensor was developed with a 98-106 % recovery rate in spiked biological samples. It shows the potential applicability of the developed immunoelectrode.


Assuntos
Técnicas Biossensoriais , Grafite , Nanopartículas Metálicas , Staphylococcus aureus Resistente à Meticilina , Nanocompostos , Grafite/química , Ouro/química , Técnicas Eletroquímicas/métodos , Espectroscopia de Infravermelho com Transformada de Fourier , Técnicas Biossensoriais/métodos , Nanopartículas Metálicas/química , Imunoensaio , Anticorpos , Nanocompostos/química , Limite de Detecção
14.
Anal Chim Acta ; 1299: 342377, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38499410

RESUMO

In this study, the electrochemical properties of etofenamate, an active ingredient belonging to the non-steroidal anti-inflammatory drug group, were investigated using cyclic voltammetry (CV) and square wave voltammetry (SW) techniques on a disposable pencil graphite electrode (PGE). With the CV technique, reversible voltammetric waves of around +0.470 V and irreversible voltammetric waves of around +1.02 V were produced on the PGE. An environmentally friendly, selective and highly sensitive SW voltammetric method was developed using disposable PGE. This voltammetric method gave very good analytical working range on PGE in PBS (pH = 3.0) medium at concentrations ranging from 0.017 µM to 0.306 µM. The LOD value of this analytical method in PBS (pH = 3.0) medium was calculated as 0.0011 µM (0.406 µg L-1). The developed voltammetric method was successfully applied to urine and drug samples. The results of the voltammetric method were compared with the results of the spectrophotometric method. The results were found to be compatible with each other.


Assuntos
Ácido Flufenâmico/análogos & derivados , Grafite , Grafite/química , Eletrodos , Anti-Inflamatórios , Técnicas Eletroquímicas/métodos
15.
Nat Commun ; 15(1): 2225, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38472177

RESUMO

Single-particle cryo-EM is widely used to determine enzyme-nucleosome complex structures. However, cryo-EM sample preparation remains challenging and inconsistent due to complex denaturation at the air-water interface (AWI). Here, to address this issue, we develop graphene-oxide-coated EM grids functionalized with either single-stranded DNA (ssDNA) or thiol-poly(acrylic acid-co-styrene) (TAASTY) co-polymer. These grids protect complexes between the chromatin remodeler SNF2h and nucleosomes from the AWI and facilitate collection of high-quality micrographs of intact SNF2h-nucleosome complexes in the absence of crosslinking. The data yields maps ranging from 2.3 to 3 Å in resolution. 3D variability analysis reveals nucleotide-state linked conformational changes in SNF2h bound to a nucleosome. In addition, the analysis provides structural evidence for asymmetric coordination between two SNF2h protomers acting on the same nucleosome. We envision these grids will enable similar detailed structural analyses for other enzyme-nucleosome complexes and possibly other protein-nucleic acid complexes in general.


Assuntos
Grafite , Nucleossomos , Grafite/química , Microscopia Crioeletrônica , Água
16.
Biosensors (Basel) ; 14(3)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38534228

RESUMO

Development of an efficient technique for accurate and sensitive dibutyl phthalate (DBP) determination is crucial for food safety and environment protection. An ultrasensitive molecularly imprinted polymers (MIP) voltammetric sensor was herein engineered for the specific determination of DBP using poly-l-lysine/poly(3,4-ethylenedioxythiophene)/porous graphene nanocomposite (PLL/PEDOT-PG) and poly(o-phenylenediamine)-imprinted film as a label-free and sensing platform. Fabrication of PEDOT-PG nanocomposites was achieved through a simple liquid-liquid interfacial polymerization. Subsequently, poly-l-lysine (PLL) functionalization was employed to enhance the dispersibility and stability of the prepared PEDOT-PG, as well as promote its adhesion on the sensor surface. In the presence of DBP, the imprinted poly(o-phenylenediamine) film was formed on the surface of PLL/PEDOT-PG. Investigation of the physical properties and electrochemical behavior of the MIP/PLL/PEDOT-PG indicates that the incorporation of PG into PEDOT, with PLL uniformly wrapping its surface, significantly enhanced conductivity, carrier mobility, stability, and provided a larger surface area for specific recognition sites. Under optimal experimental conditions, the electrochemical response exhibited a linear relationship with a logarithm of DBP concentration within the range of 1 fM to 5 µM, with the detection limit as low as 0.88 fM. The method demonstrated exceptional stability and repeatability and has been successfully applied to quantify DBP in plastic packaging materials.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Grafite , Impressão Molecular , Nanocompostos , Fenilenodiaminas , Polímeros , Dibutilftalato , Polímeros Molecularmente Impressos , Técnicas Eletroquímicas/métodos , Grafite/química , Polilisina , Porosidade , Nanocompostos/química , Impressão Molecular/métodos , Limite de Detecção , Eletrodos
17.
Environ Pollut ; 348: 123884, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38548155

RESUMO

The most recent structural study of graphene oxide (GO) indicates that the oxidized debris (ODs) adhered to as-prepared GO will strip in certain aquatic settings. The impact of ODs stripping on the characteristics of GO has been widely reported, but its effects on GO aggregation have received less attention. Here, the influence of OD stripping on the GO aggregation property was identified, and the aggregation of as-prepared GO and GO upon OD stripping was compared. Upon ODs stripping, the pKa values of GO shifted from 3.91, 6.25, and 9.84 to 4.54, 6.65, and 10.21, respectively. Further analysis indicated the removal of ODs reduced the net negative charge and improved the hydrophobicity of GO, hence promoting the aggregation of GO. The acceleration of GO-Ca2+-OD aggregate formation was facilitated by the collective effects of ODs stripping, functional group deprotonation, double layer compression, OD bridging, and charge neutralization. The metal ions and stripped ODs attach to GO edges and link GO, which perform like bridges and contribute to further aggregation. In general, the existence of ODs adds complexity to the constructions and characteristics of GO, and it is important to take this into account while evaluating the aggregation characteristic of GO-based materials.


Assuntos
Grafite , Simulação de Dinâmica Molecular , Óxidos/química , Água/química , Grafite/química
18.
Anal Methods ; 16(15): 2256-2266, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38517319

RESUMO

A conductive nanocomposite consisting of heparin-stabilized gold nanoparticles embedded in graphene was prepared and characterized to develop an electrochemical sensor for the determination of esculetin in tea and jam samples. The gold nanoparticles were characterized by spectroscopic and microscopic techniques. The different proportions of graphene in the nanocomposite were evaluated and characterized by electrochemical practices. The heterostructure material on the glassy carbon electrode with esculetin showed π-π stacking interactions with an adsorption-controlled process. The voltammetric profile of esculetin using the proposed nanomaterial presented oxidation and reduction peaks at +0.61 and +0.58 V vs. Ag/AgCl, respectively, facilitating the electron transfer with esculetin through the transfer of two moles of protons and two moles of electrons per mole of esculetin. Using optimized conditions and square wave voltammetry, the calibration curve was obtained with two linear ranges, from 0.1 to 20.5 µmol L-1, with a detection limit of 43.0 nmol L-1. The electrochemical sensor showed satisfactory results for repeatability and stability, although interferences were observed in the presence of high concentrations of ascorbic acid or quercetin. The sensor was successfully applied in the determination of esculetin in samples of mulberry jam, white mulberry leaf tea, and white mulberry powder tea, presenting adequate recovery ranges. This directive provides valuable insights for the development of novel electrochemical sensors using heparin-based conductive nanomaterials with improved sensitivity and sensibility.


Assuntos
Grafite , Nanopartículas Metálicas , Toupeiras , Umbeliferonas , Animais , Grafite/química , Ouro/química , Heparina , Nanopartículas Metálicas/química , Chá
19.
Environ Sci Pollut Res Int ; 31(17): 25437-25453, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38472573

RESUMO

2,4-Dichlorophenoxyacetic acid (2,4-D) is an herbicide and is among the most widely distributed pollutant in the environment and wastewater. Herein is presented a complete comparison of adsorption performance between two different magnetic carbon nanomaterials: graphene oxide (GO) and its reduced form (rGO). Magnetic functionalization was performed employing a coprecipitation method, using only one source of Fe2+, requiring low energy, and potentially allowing the control of the amount of incorporated magnetite. For the first time in literature, a green reduction approach for GO with and without Fe3O4, maintaining the magnetic behavior after the reaction, and an adsorption performance comparison between both carbon nanomaterials are demonstrated. The nanoadsorbents were characterized by FTIR, XRD, Raman, VSM, XPS, and SEM analyses, which demonstrates the successful synthesis of graphene derivate, with different amounts of incorporate magnetite, resulting in distinct magnetization values. The reduction was confirmed by XPS and FTIR techniques. The type of adsorbent reveals that the amount of magnetite on nanomaterial surfaces has significant influence on adsorption capacity and removal efficiency. The procedure demonstrated that the best performance, for magnetic nanocomposites, was obtained by GO∙Fe3O4 1:1 and rGO∙Fe3O4 1:1, presenting values of removal percentage of 70.49 and 91.19%, respectively. The highest adsorption capacity was reached at pH 2.0 for GO∙Fe3O4 1:1 (69.98 mg g-1) and rGO∙Fe3O4 1:1 (89.27 mg g-1), through different interactions: π-π, cation-π, and hydrogen bonds. The adsorption phenomenon exhibited a high dependence on pH, initial concentration of adsorbate, and coexisting ions. Sips and PSO models demonstrate the best adjustment for experimental data, suggesting a heterogeneous surface and different energy sites, respectively. The thermodynamic parameters showed that the process was spontaneous and exothermic. Finally, the nanoadsorbents demonstrated a high efficiency in 2,4-D adsorption even after five adsorption/desorption cycles.


Assuntos
Grafite , Herbicidas , Nanocompostos , Poluentes Químicos da Água , Adsorção , Herbicidas/análise , Grafite/química , Óxido Ferroso-Férrico , Água/química , Nanocompostos/química , Fenômenos Magnéticos , Ácido 2,4-Diclorofenoxiacético , Cinética , Poluentes Químicos da Água/análise , Concentração de Íons de Hidrogênio
20.
ACS Sens ; 9(3): 1565-1574, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38447101

RESUMO

Molecular recognition and sensing can be coupled to interfacial capacitance changes on graphene foam surfaces linked to double layer effects and coupled to enhanced quantum capacitance. 3D graphene foam film electrodes (Gii-Sens; thickness approximately 40 µm; roughness factor approximately 100) immersed in aqueous buffer media exhibit an order of magnitude jump in electrochemical capacitance upon adsorption of a charged molecular receptor based on pyrene-appended boronic acids (here, 4-borono-1-(pyren-2-ylmethyl)pyridin-1-ium bromide, or abbreviated T1). This pyrene-appended pyridinium boronic acid receptor is employed here as a molecular receptor for lactate. In the presence of lactate and at pH 4.0 (after pH optimization), the electrochemical capacitance (determined by impedance spectroscopy) doubles again. Lactic acid binding is expressed with a Hillian binding constant (Klactate = 75 mol-1 dm3 and α = 0.8 in aqueous buffer, Klactate = 460 mol-1 dm3 and α = 0.8 in artificial sweat, and Klactate = 340 mol-1 dm3 and α = 0.65 in human serum). The result is a selective molecular probe response for lactic acid with LoD = 1.3, 1.4, and 1.8 mM in aqueous buffer media (pH 4.0), in artificial sweat (adjusted to pH 4.7), and in human serum (pH adjusted to 4.0), respectively. The role of the pyrene-appended boronic acid is discussed based on the double layer structure and quantum capacitance changes. In the future, this new type of molecular capacitance sensor could provide selective enzyme-free analysis without analyte consumption for a wider range of analytes and complex environments.


Assuntos
Grafite , Ácido Láctico , Humanos , Ácido Láctico/análise , Grafite/química , Ácidos Borônicos/química , Suor/química , Eletrodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...